2. You do not need any power, USB cable will supply power from your computer to your guitar. If USB connected, the blue light will turn on. After USB connected, your computer will install new hardware device driver. Allow your computer to install the hardware device driver. After installation completed, please disconnect your USB cable.
3. Now you need to install the guitar’s driver. Find the folder “Driver” from your installation CD and find “setup.exe” filename. Run it and follow the instructions.
4. Install the included software from your installation CD. Find file “setup.exe” in folder “NI Guitar Combos. Run it and follow the instructions.
5. Configure the software and try to play your guitar.
For more detail installations please look this guidelines.
Troubleshootings
ISSUE: USB AUDIO Codec not recognized by Windows; no entry for USB AUDIO Device in Windows Device Manager
# Check USB connection, if possible try different USB cable or USB port.
# Connect iAXE guitar directly to computer, not via USB hub.
# Ensure that USB port is functional (does it work with digital camera, printer, etc.?).
# If necessary, check that USB ports are activated in host system BIOS.
ISSUE: Windows driver installation not completed (for example, Windows error code 10, error code 39)
# Check USB connection, if possible try different USB cable or USB port.
# Connect iAXE guitar directly to computer, not via USB hub.
# If possible, try to install on another computer.
ISSUE: During installation, warning is displayed “target file exists and is newer than the source”
# Choose option “Overwrite newer file”.
ISSUE: Installation of BEHRINGER USB AUDIO driver failed with “Error 0×0006”
# Check USB connection, if possible try different USB cable or USB port.
# Close application, re-run the BEHRINGER USB AUDIO setup.exe file from CD-ROM.
# Download fresh ASIO driver files from www.behringer.com
ISSUE: ASIO-USB Control Panel 2.7.8 does not show BEHRINGER USB AUDIO as Device
# Check USB connection, if possible try different USB cable or USB port.
# Connect iAXE guitar directly to computer, not via USB hub.
# Close application, reinstall ASIO driver (BEHRINGER USB AUDIO setup.exe file) and try again.
ISSUE: Latency time too long
# Reduce latency setting.
# Start “ASIO-USB Control Panel 2.7.8” from within audio software (called “ASIO configuration” or similar).
# Set USB Device to BEHRINGER USB AUDIO.
# Click on ASIO tab.
# Set System Performance to “Rapid” (or even “High speed”).
ISSUE: Clicks or dropouts in recording (latency time too short)
# Increase latency setting.
# Start “ASIO-USB Control Panel 2.7.8” from within audio software (may be called “ASIO
configuration” or similar).
# USB Device = BEHRINGER USB AUDIO.
# Click on ASIO tab.
# Set System Performance to Normal.